CW-6000 Air-Cooled Chiller CO2 Laser Recirculating Water Cooler Essential Pump Compressor PLC Engine Bearing Direct Supplier

Whether in metal processing, wood cutting or laser processing of other materials, CW6000 laser cooling chillers can provide reliable cooling solutions to ensure cutting quality and production efficiency.

Product Description

CW6000 Water Chiller Machine Specifications

Model
CW-6000
Voltage
AC 220-240V
AC 220-240V
AC 110V
Freguency
50HZ
60HZ
60HZ
Working current
3.2-8.6A
0.4-9.2A
0.4-17.2A
Compressor power
1050W
1060W
810W
1.2HP
1.2HP
1HP
Rated power of the whole machine
3KW ±5%
3KW ±5%
2.6KW +5%
Refrigerant
R22/R410a
Restrictor
Capillary
Maximum head
20m
25m
30m
20m
25m
30m
20m
25m
30m
Maximum flow rate
20L/min
27L/min
80L/min
20L/min
27L/min
80L/min
20L/min
27L/min
80L/min
Water pump power
60W
88W
300W
60W
88W
300W
60W
88W
300W
Inlet and outlet
φ10Copper Tsui Pagoda(default)/φ8Connector/φ10Connector/φ12Connector
Water tank capacity
15L
Size
Length *Width *Height 740*480*840mm(L×W×H)
Net weight
65Kg
Security protection
Water flow protection, water temperature over-high alarm, water temperature over-low alarm, compressor overload protection, room temperature over-high alarm
CW-6000 Air-Cooled Chiller CO2 Laser Recirculating Water Cooler Essential Pump Compressor PLC Engine Bearing Direct Supplier manufacture
CW-6000 Air-Cooled Chiller CO2 Laser Recirculating Water Cooler Essential Pump Compressor PLC Engine Bearing Direct Supplier factory
CW-6000 Air-Cooled Chiller CO2 Laser Recirculating Water Cooler Essential Pump Compressor PLC Engine Bearing Direct Supplier factory

Applications of CW-6000 Air Cooled Chiller

CW-6000 laser cooling chillers are widely used in many industries, mainly to provide stable cooling solutions. For example, CNC industry, machinery industry, chemical industry, etc. CW-6000 air-cooled chillers have become an indispensable cooling solution in many industries with their efficient cooling capacity, stable performance and easy maintenance.

Application of CO2 <a class='inkey' style='color:blue' href='https://www.zblizhiyuan.com/product' target='_blank'>Laser chiller</a>.jpg

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

Have any questions?

If you have any questions about our industrial chillers or services, or require further information, please feel free to contact us.

Why Choose Us

Since its establishment in 2012, the company has been deeply engaged in the research and development, production, and sales of industrial chiller series products.

  • Provide free warranty service, free repair or replacement of parts due to quality problems. Provide free warranty service, free repair or replacement of parts due to quality problems.

    Provide free warranty service, free repair or replacement of parts due to quality problems.

  • Annual shipments exceed 100,000 units, leading the industry Annual shipments exceed 100,000 units, leading the industry

    Annual shipments exceed 100,000 units, leading the industry

  • Diversified layout from industrial chillers, fiber laser chillers to UV/ultrafast laser chillers Diversified layout from industrial chillers, fiber laser chillers to UV/ultrafast laser chillers

    Diversified layout from industrial chillers, fiber laser chillers to UV/ultrafast laser chillers

  • The product is available in a variety of specifications and models and can be customized. The product is available in a variety of specifications and models and can be customized.

    The product is available in a variety of specifications and models and can be customized.

ZIBO LIZHIYUAN

Frequently Asked Questions about Chillers

Here you can see some common questions about chillers, hope it can help you

Frequently Asked Questions about Chillers

We are a professional industrial chiller manufacturer.

The ideal water should be deionized water, distilled water, or purified water.

Generally speaking, the recommended frequency for changing water is every 3 months. It can also depend on the actual working environment of the recirculating water chillers. For example, if the working environment is too poor, it is recommended to change the frequency to once a month or less.

The working environment of the industrial water chiller should be well-ventilated, and the room temperature should not exceed 45 degrees Celsius.

For users residing in high latitude areas, particularly during winter, they frequently encounter the problem of frozen water. To prevent the chiller from freezing, one can add an optional heater or antifreeze to the chiller. For detailed instructions on using the antifreeze, please contact our customer support team.
Tel
86-18053388009
E-mail
[email protected]
Address
100 Meters West Of Xinzhuang Community Neighborhood Committee, Zhonglou Street, Zibo, Shandong, China
Follow Us

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
Recommended Products